Generator Load Bank Testing Requirements
In addition to routine maintenance you ll also need to conduct ongoing operational tests of your epss.
Generator load bank testing requirements. The frequency schedule for load bank testing on a generator often depends on how the generator is classified and what it is a standby for. A load bank can be connected to the generator to get above the 30 requirement. At 25 of the nameplate kilowatt rating for 30 minutes. It verifies that all primary components of the generator set are in proper working condition under loaded conditions.
The testing for an annual load bank test and the triennial exercise may be combined according to nfpa 110 2010. Emergency power generation systems fall under a number of regulatory oversight conditions and code requirements. 1 1 1 power systems covered in this standard include power sources transfer equipment controls supervisory equipment and all related electrical. This standard contains requirements covering the performance of emergency and standby power systems providing an alternate source of electrical power to loads in buildings and facilities in the event that the primary power source fails.
8 4 2 3 has special requirements for diesel generators that can t meet the minimum exhaust temps or 30 load requirements. Any examples are for illustrative purposes only. For example if a generator is used as a backup for services associated with loss of life or serious injury such as in a hospital setting the testing requirements are much more frequent. For gasoline powered natural gas powered or propane powered generators that do not meet the testing requirements outlined in 1 a above it will likely be necessary to add more load to the generator or conduct a load bank test to comply with testing requirements a load bank is typically a mobile piece of equipment that simulates the actual.
Prechecks 1 fuel fluid levels belts hold down bolts etc. The purpose of these tests are to periodically verify the function of the system against the standard. During this two hour period the unit should be operated as follows. Generator engine and load bank testing outline a.
Load bank testing for two continuous hours each year. Can the generator load bank test be combined to meet the 36 month test as well as the 4 hour load test. 8 2 4 3 if a generator fails the monthly test it should be operated under a load supplied by a load bank i e. Ongoing requirements according to nfpa 110 chapter 8.
Load bank testing shall be performed for a period of four 4 hours at the full rated load of the generator and witnessed by a county representative.