Gas Furnace Vent Pipe Size
Connectors single wall pipe stovepipe is not recommended for use in type b venting systems.
Gas furnace vent pipe size. This determines the size of vent pipe fittings and flashing needed to install the vent system. Atype b vent lining an exposed masonry chimney is considered to be an enclosed vent system and these tables may be used. When we are talking about gas furnace vent pipe code we need to talk about the different types of the vents first after all you want to keep your family safe from harm. For many homes a gas furnace is the preferred heating device it has proven to be an efficient and reliable way of meeting household heating needs over the years.
C gas pipe connection size d flue collar outlet size nate. Traditional gas fired forced air furnaces produce hot combustion exhaust gasses and therefore need metal vent pipes or chimneys. A simple 1 fiberglass filter will protect the blower and. Well the furnace nametag tells us that the furnace has a rating of 130 000 btu input the collar size is 4 in and the furnace is a natural draft.
Duravent 4 x 6 5 8 directvent pro direct vent pipe double wall co linear masonry chimney conversion kit with flex pipe and prairie cap model. Any resulting gas byproducts are cool enough to vent them outside through a pvc pipe. The condensed water is run to a floor drain. In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents some high efficiency furnaces also include a plastic pipe for intake area and all types.
Gas vents 12 inches 305 mm in size or smaller with listed caps shall be permitted to be terminated in accordance with figure g2427 6 5 provided that such vents are at least 8 feet 2438 mm from a vertical wall or similar obstruction. Change the furnace filters at least every three months. The vent pipe or flue is a vital component of the furnace that transmits emissions from the combustion process out of the building. Measure the diameter of the circular flange where the vent attaches at the back of the furnace.
Change the air filters regularly. As noted 4yr old gas furnace vent pipes run straight across walk out basement and out the rear wall. The gas vent sizing tables are not applicable to outside exposed chimneys or vents below the roofline per nfpa 54. Before we leave the shop let s check the furnace to get the rating flue collar size and the installation instructions.
If you have pets you should do it more frequently. Well making sure that you choose the right venting style will protect them.